首页> 外文会议>11th fuel cell science, engineering, and technology conference 2013 >DESIGN AND EXPERIMENTAL INVESTIGATION OF A HEAT PIPE SUPPORTED EXTERNAL COOLING SYSTEM FOR HT-PEFC FUEL CELL STACKS
【24h】

DESIGN AND EXPERIMENTAL INVESTIGATION OF A HEAT PIPE SUPPORTED EXTERNAL COOLING SYSTEM FOR HT-PEFC FUEL CELL STACKS

机译:HT-PEFC燃料电池堆热管支撑式外部冷却系统的设计与实验研究

获取原文
获取原文并翻译 | 示例

摘要

A 10-cells HT-PEFC stack with an active cell area of 200 cm~2 has been built up and tested regarding the temperature distribution from cell to cell and over the active area since not every cell is cooled. Measurements with artificial reformate as a fuel show that the vertical temperature distribution over the active area is sufficiently small, with a maximum of 5.1 K at 550 mA cm~(-2) . Also the temperature gradient from cell to cell is sufficiently small with 10.7 K at 550 mA cm~(-2). As a result it can be mentioned, that the heat pipe supported external cooling is well suited to cool HT-PEFC stacks with large active areas in reformate operation.
机译:由于不是每个电池都被冷却,因此已经构建了一个具有200 cm〜2的活动电池区域的10电池HT-PEFC堆栈,并进行了测试,以测试从一个电池到另一个电池以及整个活动区域的温度分布。用人工重整产品作为燃料进行的测量表明,有效区域上的垂直温度分布足够小,在550 mA cm〜(-2)时最大为5.1K。电池之间的温度梯度也足够小,在550 mA cm〜(-2)时为10.7K。结果,可以说,热管支撑的外部冷却非常适合于在重整产品运行中冷却具有大有效面积的HT-PEFC堆。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com