首页> 外文会议>14th cryogenics 2017 >A HYDROSTATIC PRESSURIZATION TEST OF HIGH PRESSURE HELIUM GAS STORAGE VESSELS AT IPR
【24h】

A HYDROSTATIC PRESSURIZATION TEST OF HIGH PRESSURE HELIUM GAS STORAGE VESSELS AT IPR

机译:高压氦气储气罐的静水加压试验

获取原文
获取原文并翻译 | 示例

摘要

In IPR, helium gas high pressure storage pressures vessels installed for gas inventory of liquid helium plant.rnAs a part of CCOE and safety regulation, it is mandatory requirement to have hydrostatic pressurization test,rnnon-destructive tests and physical inspection of these vessels as per SMPV 19(U) rule for its license approvalrnin every five years. We have carried out the hydrostatic tests of these vessels complying with CCOE norms.rnIt needs special precautionary measures that the dealing of high pressure of more than 200 bar (g), heliumrnleak tightness at high pressure, moisture level assurance of less than 2 ppm in the vessel are critical from thernhelium plant operation. We will report the hydrostatic test procedures, NDT test, moisture removal, vacuumrnevacuation and gas purging, helium leak test of vessels at operating pressure. At present, after obtaining thernoperation license, all vessels are in operation without any technical issues.
机译:在IPR中,安装了用于存储液氦厂气体的氦气高压存储压力容器.rn作为CCOE和安全法规的一部分,必须对这些容器进行静水压力试验,无损检测和物理检查,这是强制性要求SMPV 19(U)规则每五年批准一次。我们已经对这些符合CCOE规范的容器进行了静水压力试验.rn需要采取特殊的预防措施,以应对200 bar(g)以上的高压,在高压下氦气密封性,在20 ppm内确保水分含量小于2 ppm该船对地热工厂的运营至关重要。我们将报告在工作压力下的容器的静水压测试程序,NDT测试,除湿,真空抽真空和气体净化,氦气泄漏测试。目前,所有船舶在获得营业执照后均在运行,没有任何技术问题。

著录项

  • 来源
    《14th cryogenics 2017》|2017年|508-513|共6页
  • 会议地点
  • 作者单位

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India,rajivs@ipr.res.in;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

    Institute for Plasma Research Near Indira Bridge, Bhat, Gandhinagar, Gujarat -382 428, India;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号