首页> 外文会议>14th international conference amp; exhibition on liquefied natural gas (LNG 14) >INVESTIGATIONS INTO THE AGING EXTENT OF THE 9 NICKEL 500 M3 LNG STORAGE TANK OF THE NANTES CRYOGENIC TESTING STATION
【24h】

INVESTIGATIONS INTO THE AGING EXTENT OF THE 9 NICKEL 500 M3 LNG STORAGE TANK OF THE NANTES CRYOGENIC TESTING STATION

机译:南特低温测试站的9%镍500 M3液化天然气储罐老化程度的调查

获取原文
获取原文并翻译 | 示例

摘要

Gaz de France has been operating its Liquefied Natural Gas (LNG) Testing Station, located in Nantes near the Montoir methane terminal, for more than 40 years. This Testing Station, which was launched with the construction in 1959 and commissioning in 1960 of a 500 m3 9% nickel steel self-sustaining above ground LNG tank, allowed the qualification of various cryogenic installations and equipment, including the 9% nickel steel inner wall storage tank technique, an open-rack aluminum MARSTON type regasification unit and other equipment such as valves and flanges. rnRecently, the decision was made by Gaz de France to close down the Nantes Testing Station by the end of 2001 and the Testing Station was dismantled from September 2002 to March 2003. The dismantling of the Nantes Testing Station represents a unique and unprecedented opportunity to study the aging extent of various cryogenic materials commonly used in the LNG industry, some of which have been operated for more than 40 years at LNG temperatures. In particular, the 9% nickel steel inner walls of the 500 m3
机译:法国天然气工业公司(Gas de France)的液化天然气(LNG)测试站已经运营了40多年,该站位于Montoir甲烷终端附近的南特。该测试站于1959年开始建造,并于1960年开始试运行,一个500 m3 9%镍钢自持地上LNG储罐,对各种低温装置和设备进行了鉴定,包括9%镍钢内壁储罐技术,开放式铝制MARSTON型再气化装置和其他设备,例如阀门和法兰。 rn最近,法国天然气工业股份公司(Gaz de France)决定在2001年底之前关闭南特测试站,并于2002年9月至2003年3月拆除该测试站。南特测试站的拆除代表了一个独特而空前的学习机会液化天然气工业中常用的各种低温材料的老化程度,其中一些已在液化天然气温度下运行了40多年。特别是500 m3的9%镍钢内壁

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号