首页> 外文会议>2001 International gas research conference >DEVELOPMENT OF 0.3MPa STEAM-RECOVERING 270kW EBULLIENT-COOLING GAS ENGINE
【24h】

DEVELOPMENT OF 0.3MPa STEAM-RECOVERING 270kW EBULLIENT-COOLING GAS ENGINE

机译:0.3MPa蒸汽回收270kW沸腾冷却燃气发动机的研制

获取原文
获取原文并翻译 | 示例

摘要

Cogeneration system furnished with gas engines produces waste heat in two forms, one as steam (usually 0.8 MPa) from the exhaust gas and the other as hot water from the coolant of an engine. The usages of hot water are limited because its temperature is approximately 90℃, and a pump for hot water and a radiator unit for controlling coolant temperature are required. On the other hand, steam is easy to utilize for heating. An ebullient-cooling gas engine (power output: 270 ekW), whose coolant is pressurized to 0.3 MPa and which can directly take out 0.3MPa steam has been developed. Improvements of its performance were made and evaluation tests were conducted by 1998 in the test bench. Then, cogeneration package using this engine at a user's facility began to operate in July 1999 and inspection at 4000h and 8000h operation was conducted.
机译:配备有燃气发动机的热电联产系统会产生两种形式的废热,一种为废气的蒸汽(通常为0.8 MPa),另一种为发动机冷却液的热水。热水的使用受到限制,因为其温度约为90℃,因此需要用于热水的泵和用于控制冷却液温度的散热器单元。另一方面,蒸汽易于用于加热。已经开发出沸腾冷却的燃气发动机(功率输出:270 ekW),其冷却剂被加压至0.3 MPa,并且可以直接排出0.3 MPa的蒸汽。它的性能得到了改进,并于1998年在测试台上进行了评估测试。然后,使用该发动机的热电联产包装在用户的工厂于1999年7月开始运行,并在4000h和8000h运行时进行了检查。