首页> 外文会议>2010 inorganic contaminants workshop >Combining Biological and Traditional Treatment for Iron and Manganese Removal Presented at 2010 Inorganics Chemical Workshop, Denver, CO March 1, 2010
【24h】

Combining Biological and Traditional Treatment for Iron and Manganese Removal Presented at 2010 Inorganics Chemical Workshop, Denver, CO March 1, 2010

机译:生物与传统处理相结合的除铁和除锰技术在美国丹佛市2010无机化学研讨会上发表2010年3月1日

获取原文
获取原文并翻译 | 示例

摘要

This paper presents the use of a two-stage filtration process for groundwater systemsrnwith high levels of iron and manganese. The process combines biological iron removal andrnmanganese dioxide removal processes to allow immediate start-up of systems, improve removalrnefficiency and reduce operating costs. Results from three systems are presented, that combinernboth full scale and pilot testing results. The results show that raw water iron levels were reducedrnfrom 6 mg/L, 6.5 mg/L and 12 mg/L in three systems to less than one mg/L in the first biologicalrnstage. The second stage using chlorine or permanganate as an oxidant, reduced iron andrnmanganese levels to well below the secondary MCLs of 0.3 mg/L for iron and 0.05 mg/L forrnmangananese.
机译:本文介绍了在高铁和锰含量的地下水系统中采用两阶段过滤工艺的方法。该工艺结合了生物除铁和二氧化锰去除工艺,可以立即启动系统,提高去除效率并降低运营成本。给出了三个系统的结果,这些系统将全面测试结果和中试测试结果结合在一起。结果表明,在第一个生物阶段,原水铁含量从三个系统中的6 mg / L,6.5 mg / L和12 mg / L降低到不足1 mg / L。第二阶段使用氯气或高锰酸盐作为氧化剂,将铁和锰的锰含量降低到远低于铁的二次MCL(0.3 mg / L和锰的0.05 mg / L)。