The San Jose Water Company (SJWC) owns and operates the Montevina Water Treatment Plant (Montevina WTP) in Los Gatos, California. The 30 MGD capacity Montevina WTP treats surface water from the local watershed by coagulation, hydraulic flocculation, granular media filtration, and chlorine disinfection. Pilot testing of membrane filtration technology was conducted as part of the Facility Plan for improvements to the Montevina WTP. The pilot testing of membrane technologies was conducted at the Ostwald intake site from February through May of 2010. The pilot testing was performed during the wet season (with the more challenging source water conditions) and operated through over a dozen high turbidity storm events.rnThree different types of membrane filtration (MF) pilot systems were tested to confirm that the technology would work as expected with the "flashy" source water conditions and to develop project specific design and operating criteria. The pilot testing of different manufacturer's systems also permits a more competitive selection process for the membrane equipment. The Kruger system utilized pressure ceramic MF technology, the Pall Corporation system utilized pressure polymeric (PVDF) MF technology and the Siemens-Memcor system utilized submerged PVDF MF technology.rnThe pilot testing successfully demonstrated the ability of the membrane alternative treatment process to meet the water treatment requirements and objectives for the project including turbidity and TOC removal. Furthermore, all three MF systems operated successfully through the "flashy" storm event water conditions, maintaining stable filtration rates and operating with an appropriate membrane cleaning strategy. This paper presents the water quality results and the membrane design criteria for the membrane equipment based on the pilot performance and operating data for the three MF systems.
机译:San Jose自来水公司(SJWC)在加利福尼亚州洛斯加托斯拥有并运营着Montevina水处理厂(Montevina WTP)。容量为30 MGD的Montevina WTP通过凝结,水力絮凝,颗粒介质过滤和氯消毒处理本地流域的地表水。膜过滤技术的试点测试是设施计划的一部分,旨在改善Montevina WTP。膜技术的中试试验于2010年2月至2010年5月在Ostwald取水场进行。中试在雨季(水源条件更具挑战性)下进行,并经历了十多次高浊度暴风雨事件。测试了不同类型的膜过滤(MF)中试系统,以确认该技术在“浮水”水源条件下可以正常工作,并制定了项目特定的设计和操作标准。对不同制造商系统的先导测试还使膜设备的选择过程更具竞争性。克鲁格(Kruger)系统利用压力陶瓷MF技术,颇尔公司(Pall Corporation)系统利用压力聚合物(PVDF)MF技术,西门子-默科(Siemens-Memcor)系统利用浸没式PVDF MF技术.rn试点测试成功证明了膜替代处理工艺满足水质的能力。该项目的处理要求和目标,包括浊度和TOC去除。此外,所有三个MF系统在“暴雨”暴雨水条件下均能成功运行,保持稳定的过滤速度并采用适当的膜清洁策略运行。本文基于三种MF系统的试验性能和运行数据,介绍了膜设备的水质结果和膜设计标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号