Three conventional control techniques for extracting reference currents for shunt active power filters have been assessed and their performances have been compared with a novel fuzzy logic based control technique. Critical analysis of Comparison of the compensation ability of different control strategies based on THD and speed will be done and suggestions will be given for the selection of technique to be used. The simulated results using MATLAB model are presented and they will clearly prove the value of the proposed control method of aircraft shunt APF
机译:已经评估了三种用于提取并联有源功率滤波器参考电流的常规控制技术,并将其性能与基于新颖模糊逻辑的控制技术进行了比较。对基于总谐波失真和速度的不同控制策略的补偿能力的比较进行了批判性分析,并为选择使用的技术提供了建议。给出了用MATLAB模型进行的仿真结果,可以清楚地证明所提出的飞机并联APF控制方法的价值。