In recent years voltage unbalance and fault analysis in induction motor independently has been researched by engineers dealing with power quality issues. The exposure of the motor to unbalanced supply, combined with broken rotor bar fault significantly increases the temperature and reduces the efficiency and life of the motor. In this paper the effect of unbalance on broken rotor bar fault of the squirrel cage induction motor is analyzed. The performance of the induction motor is studied using symmetrical component analysis for the extracted stator current. The electromagnetic torque is analyzed, and is found to give sufficient information about the fault and the unbalance condition. The simulation of the proposed methodology is done using MATLAB SIMULINK.
机译:近年来,处理电能质量问题的工程师已经独立研究了感应电动机中的电压不平衡和故障分析。电机暴露于不平衡的电源中,再加上转子条故障而大大提高了温度,并降低了电机的效率和寿命。本文分析了不平衡对鼠笼式感应电动机转子断条故障的影响。使用对称分量分析对提取的定子电流进行研究,以研究感应电动机的性能。对电磁转矩进行分析,发现该电磁转矩可提供有关故障和不平衡状况的足够信息。所提出方法的仿真是使用MATLAB SIMULINK完成的。