The performance characteristics of the South African Lightning Detection Network (SALDN) are evaluated using photographed lightning attachments to a tall structure over a four year period (2009-2013) after increased numbers (19 to 24) and repositioning of sensors in 2011. The structure is not instrumented and the evaluation only focuses on flash detection efficiency and location accuracy. During the four year period, 66 flashes to the tower were photographed and 185 negative SALDN strokes in 39 flashes were time-correlated with the photographs. It is seen that the flash detection efficiency increased from 50% to 76% after the upgrade with this being considered a low estimate given the majority of events are upward in nature. The median location accuracy is found to be 280 m and maximum location error is decreased after the upgrade.
机译:南非雷电检测网络(SALDN)的性能特征是通过在四年内(2009年至2013年)用拍照的雷电附着物对高建筑物进行评估的,该数目在增加(19至24)并在2011年重新放置传感器后进行了评估。不会进行检测,评估仅关注闪光检测效率和位置精度。在四年期间,拍摄了66幅向塔的闪光的照片,其中39幅闪光的185个SALDN负笔画与这些照片在时间上相关。可以看出,升级后,闪光灯检测效率从50%提高到76%,考虑到大多数事件本质上都是向上的,因此这被认为是一个较低的估计值。发现升级后中位定位精度为280 m,最大定位误差减小。