The paper proposes a design scheme of integrated supervisory control system which is suitable for both 110kV dry-type transformer and intelligent substation. Some special problems such as how to measure temperature in the high voltage winding is discussed in the paper. Fiber grating sensor is used in the system because of its strong anti-interference ability and accuracy for temperature. The installation method, quantity and trace of fiber are also discussed. The grounded current of core and working current could be monitored through the high precision current transformer. The supervisory and control intelligent electronic device (IED) is used the modular design method based on high-performance ARM processor in order to improve the hardware and software efficiency. It receives the value of winding and core temperature, ambient temperature, grounded current, and analyzes the status of transformer. According to the data the IED could control the cooling fan to reduce the temperature. The IED also can deliver the data to substation control layer using IEC 61850. The comprehensive application server could display the panoramic data such as monitoring and warning data of transformer.
机译:提出了一种适用于110kV干式变压器和智能变电站的综合监控系统设计方案。本文讨论了一些特殊问题,例如如何测量高压绕组中的温度。由于其强大的抗干扰能力和对温度的准确性,因此在系统中使用了光纤光栅传感器。还讨论了光纤的安装方法,数量和走线。铁芯的接地电流和工作电流可以通过高精度电流互感器进行监控。监控智能电子设备(IED)采用基于高性能ARM处理器的模块化设计方法,以提高软硬件效率。它接收绕组和铁心温度,环境温度,接地电流的值,并分析变压器的状态。根据数据,IED可以控制冷却风扇降低温度。 IED还可以使用IEC 61850将数据传送到变电站控制层。综合的应用服务器可以显示全景数据,例如变压器的监视和警告数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号