We propose a new compression technique which exploits the high correlations between the consecutive beats of an Electrocardiogram (ECG). A single progressive average beat (PAB) and residues were computed from every 10 ECG beats and subjected to compression using Discrete Wavelet Transform (DWT). Reconstruction errors were controlled by selective reconstruction of the wavelet coefficients from the PAB and residues using 5% PRDN and 99% energy reconstruction efficiency (ERE) criteria. Finally, the selected coefficients were encoded using a lossless compressor, a combination of delta and run length encoder. An average CR and absolute maximum error of 8.96, and 0.08 mV respectively were obtained with 32 numbers of MITA data under Physionet. Major clinical features like QRS amplitude, T height, P height and QT interval had low distortion when the target PRDN limit was relaxed up to 15%.
机译:我们提出了一种新的压缩技术,该技术利用了心电图(ECG)的连续搏动之间的高度相关性。每10个ECG搏动计算一次累进平均搏动(PAB)和残差,并使用离散小波变换(DWT)进行压缩。通过使用5%PRDN和99%能量重建效率(ERE)标准从PAB和残基选择性重建小波系数来控制重建误差。最后,使用无损压缩器,增量和游程编码器的组合对所选系数进行编码。在Physionet下使用32个MITA数据获得的平均CR和绝对最大误差分别为8.96和0.08 mV。当目标PRDN限制放宽至15%时,QRS幅度,T高度,P高度和QT间隔等主要临床特征的失真较小。