During 1984-86 and during 1997/98 the NML realized the candela and lumen and used the newly realized scales as basis for participation in an international intercomparison. The luminous intensity standards (six lamps of the type Wj41/G) were measured through a V(λ) filter by means of a room temperature absolute radiometer. The luminous flux standards (six 200 W GEC luminous flux lamps) were measured on a goniophotometer by spatially integrating the illuminance distribution around the lamps. The photometer head of the goniophotometer was calibrated for illuminance by means of luminous intensity standards measured with the absolute radiometer. The purpose of this paper is to present the results of the candela and lumen realization done at the NML in 1997/98 and to compare these to the 1984-86 realization of these units at NML, and to discuss certain problems encountered during the measurement.
机译:在1984-86年和1997/98年间,NML实现了烛台和管腔的测量,并以新近实现的标度作为参加国际比对的基础。发光强度标准(六支Wj41 / G型灯)是通过V(λ)滤光片通过室温绝对辐射计测量的。通过空间积分灯周围的照度分布,在测角光度计上测量了光通量标准(六个200 W GEC光通量灯)。通过用绝对辐射计测量的发光强度标准,对测角光度计的光度计头进行照度校准。本文的目的是介绍在1997/98年在NML上完成的坎德拉和流明实现的结果,并将其与在NML上这些单元的1984-86年实现进行比较,并讨论测量过程中遇到的某些问题。