【24h】

Current Rating for Multi-Path Power Module Connectors

机译:多路径电源模块连接器的额定电流

获取原文
获取原文并翻译 | 示例

摘要

An empirical model of end-of-life performance data is used in a monte-carlo analysis to evaluate the current distribution across parallel current paths of a power module. It was shown how the expected distributions of current and voltage drop provide a method to de-rate the maximum current rating of contacts used in multi-path power applications. A number of new ideas were introduced in this paper. First, the end-of-life resistance data was used in conjunction with a monte-carlo analysis. This provided an empirically based model to determine the expected current and voltage variations. In addition, the concept of voltage drop change was applied as an end-of-life criteria to validate the maximum current rating of individual contacts. It is believed, the combined use of these concepts provides a technical basis for making decisions on current de-rating and the number of contacts needed to safely split the total current over multiple current paths.
机译:寿命终止性能数据的经验模型用于蒙特卡洛分析,以评估电源模块的并联电流路径上的电流分布。结果表明,预期的电流和电压降分布如何提供一种降低多径电源应用中使用的触点最大额定电流的方法。本文介绍了许多新想法。首先,将使用寿命终了数据与蒙特卡洛分析结合使用。这提供了基于经验的模型来确定预期的电流和电压变化。此外,电压降变化的概念被用作使用寿命终止标准,以验证各个触点的最大额定电流。可以相信,这些概念的组合使用为决定电流降额和安全地将总电流分流到多个电流路径所需的触点数量提供了技术基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有