首页> 外文会议>3rd International EMF Seminar in China: Electromagnetic Fields and Biological Effects; Oct 13-17, 2003; Guilin, China >DOSIMETRY OF MMW POWER DENSITY AND POWER ABSORPTION DENSITY FOR CELLS IN CULTURE DISHES PART Ⅰ: 6mm MMW IRRADIATION
【24h】

DOSIMETRY OF MMW POWER DENSITY AND POWER ABSORPTION DENSITY FOR CELLS IN CULTURE DISHES PART Ⅰ: 6mm MMW IRRADIATION

机译:培养皿中MMW功率密度和吸收密度的剂量学部分:第一部分:6mm MMW辐照

获取原文
获取原文并翻译 | 示例

摘要

The results illustrated in Figs. 1 to 6 provide an understanding of the MMW PD and PAD distribution in the culture solution. It is obvious that the PD and PAD are not uniform and their values change greatly with the change of position. For example, in Fig. 2a, which shows the PD distribution on the bottom of the culture solution, the PD in the darker area is only half of the PD in its adjacent brighter area, thus indicating a 8-time difference of PD on the solution bottom where the cell monolayer exists if it is the biological sample in experiments.
机译:结果示于图1和2。图1至6提供了对培养液中MMW PD和PAD分布的了解。显然,PD和PAD不一致,并且它们的值会随着位置的变化而大大变化。例如,在图2a中(显示了培养液底部的PD分布),较暗区域中的PD仅为其相邻较亮区域中PD的一半,因此表明PD在培养液底部的8倍时差如果是实验中的生物样品,则存在细胞单层的溶液底部。