首页> 外文会议>A critical link: Diagnosis to prognosis >On the corrosion of AISI 304 and galvanized steel at a meat packaging company
【24h】

On the corrosion of AISI 304 and galvanized steel at a meat packaging company

机译:关于一家肉类包装公司的AISI 304和镀锌钢的腐蚀

获取原文
获取原文并翻译 | 示例

摘要

A meat packaging and processing company had a history of corrosion problems in their smoke house facility. The rate of corrosion significantly increased shortly after an exhaust ventilator was replaced with a smaller unit and the liquid smoke solution was changed. This study determined that the new liquid smoke solution was the cause of the increased corrosion rate. Several strategies for reducing the corrosion rate are recommended and evaluated.
机译:一家肉类包装和加工公司在其烟房设施中存在腐蚀问题的历史。更换较小的排气通风机并更换烟液后不久,腐蚀率显着提高。这项研究确定了新的液体烟雾溶液是腐蚀速率增加的原因。建议并评估了几种降低腐蚀速率的策略。