Testing a high capacity filter cartridge is much more complicated than testing thernperformance of a standard 2.5 inch diameter filter. This article deals with thernvarious factors that are associated with conducting a full scale test that involvesrnflow rates as high as 800 gallons per minute, test dust capacities of up to 300rnpounds, and test pressures of 50 psid.rnThe FTC Test Lab utilizes a 6' flow loop, twin 420 gpm centrifugal pumps, 1100rngallon water storage tank, 90 gallon contaminant tank complete with injectionrnpump, flow meters, and pressure sensors. This lab can run gravimetric analysis,rnturbidity, and particle size distribution.
机译:测试大容量滤芯比测试标准2.5英寸直径滤芯的性能复杂得多。本文讨论了与进行全面测试有关的各种因素,其中涉及最大流速为800加仑/分钟,测试粉尘容量高达300rnpounds和测试压力为50psid。rnFTC测试实验室利用6'流量回路,双420 gpm离心泵,1100纳加仑的储水箱,90加仑的污染物箱,配有注射泵,流量计和压力传感器。该实验室可以进行重量分析,浊度和粒度分布。