Early on a Saturday morning, a 2-inch pipe in an unoccupied building in a plant that was shut down for the weekend ruptured violently. There were no injuries because there was nobody in the building at the time. Nearby piping was bent and ruptured by impact from the failed pipe, and there was other minor equipment damage. The released material did not ignite, and it was contained by the building spill containment system. The initial investigation of the incident determined that the ruptured pipe had been liquid filled, blocked in by closed valves, and overheated. The investigation could have stopped at that point, blaming the rupture on thermal expansion of the trapped liquid. However, a more detailed root cause investigation was done. This investigation resulted in significant new knowledge of the thermal stability of the material, which had been handled in the plant for many years, and a better understanding of the real root causes of the incident. This knowledge of potential reactive chemical hazards also resulted in redesign of the plant piping and the emergency relief systems on a number of plant vessels.
机译:周六清晨,一家工厂的一栋无人居住的建筑物中的一条2英寸长的管道因周末关闭而猛烈破裂。没有受伤,因为当时建筑物中没有人。由于故障管道的影响,附近的管道弯曲并破裂,还有其他轻微的设备损坏。释放的材料没有点燃,而是被建筑物的溢出物遏制系统所遏制。对该事件的初步调查确定,破裂的管道已充满液体,被关闭的阀门堵塞,并且过热。那时调查可能已经停止,将破裂归咎于所捕获液体的热膨胀。但是,进行了更详细的根本原因调查。这项调查使人们对材料的热稳定性有了新的认识,这种知识已经在工厂中处理了很多年,并且对事故的真正原因有了更好的了解。对潜在的化学反应性危险的了解还导致重新设计了许多工厂船舶上的工厂管道和紧急救援系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号