首页> 外文会议>Asia-Pacific Power and Energy Engineering Conference;APPEEC 2009 >An Efficient Method for Undervoltage Load Shedding
【24h】

An Efficient Method for Undervoltage Load Shedding

机译:欠压减载的有效方法

获取原文

摘要

This paper analyses the Thevenin equivalent characteristics of voltage instability by the P-V curve at the load buses. The situation and the time for load shedding are determined by identifying the weakest bus in the network by means of a voltage instability proximity index (VIPI). The index is defined by estimating Thevenin equivalent parameters using the online power flow technique. Load shedding amount is determined based on the load control of demand side management (DSM). The proposed algorithm of the efficient UVLS scheme is tested to show its effectiveness by an actual power network in China.
机译:本文通过负载母线上的P-V曲线分析了电压不稳定性的戴维南等效电压特性。通过使用电压不稳定性接近指数(VIPI)来确定网络中最弱的总线,可以确定减少负载的情况和时间。该指数是通过使用在线潮流技术估算戴维南等效参数来定义的。减载量是根据需求方管理(DSM)的负载控制确定的。通过在中国的实际电网中测试了所提出的高效UVLS方案算法,以证明其有效性。