摘要

Failure Modes And Effects Analysis (FMEA), a recognized qualitative method of risk analysis, has recently been used by Ontario Power Generation as a part of periodic dam safety reviews in conjunction with standards based reviews. This paper presents a summary of the application of the FMEA to a pilot project at the Sir Adam Beck Development Pump Generation Station dyke. It includes an overview of the FMEA outlining the purpose, process, participants and products. The benefits of the FMEA technique as an enhancement of the standards based review are demonstrated using specific examples from the FMEA of the PGS Dyke.
机译:失效模式和后果分析(FMEA)是一种公认​​的风险分析定性方法,最近已被安大略省电力公司用作定期大坝安全性审查以及基于标准的审查的一部分。本文总结了FMEA在亚当·贝克爵士发展泵发电站堤坝试点项目中的应用。它包括对FMEA的概述,概述了目的,过程,参与者和产品。使用来自PGS Dyke FMEA的特定示例,可以证明FMEA技术作为基于标准的审查的增强的好处。