首页> 外文会议>Composite Construction in Steel and Concrete VII >Performance of Composite Slabs with Profiled Sheeting Using High-Strength Steel
【24h】

Performance of Composite Slabs with Profiled Sheeting Using High-Strength Steel

机译:高强钢板异型板复合板的性能

获取原文
获取原文并翻译 | 示例

摘要

Composite slabs using cold-formed profiled steel sheeting have proved popular in multi-storey steel-framed buildings. This paper presents a comprehensive test programme that considers the performance of a modern trapezoidal profiled sheeting using Australasian 550 N/mm~2 high strength steel, compared to that exhibited by the same profile using European 350 N/mm~2 steel. Although the ductility of the Australasian steel is low, from composite slab tests it was found that the longitudinal shear behaviour could be considered ductile according to the Eurocode 4 requirements. As a consequence of this, the partial connection method was permitted. However, from the test results presented in this paper, it is shown that the rules given in Eurocode 4, Annex B.3.1 for a reduced investigation lead to unconservative results and should be revised. To remedy this situation, an amendment is proposed.
机译:事实证明,使用冷弯成型钢板的复合板在多层钢结构建筑中很受欢迎。本文介绍了一个综合测试程序,该程序考虑了使用550 N / mm〜2的澳大利亚高强度钢与现代的使用350 N / mm〜2的相同轮廓的梯形板相比的性能。尽管澳大利亚钢的延展性较低,但根据复合板坯测试发现,根据欧洲规范4的要求,可以将纵向剪切性能视为延展性。结果,允许使用部分连接方法。但是,从本文给出的测试结果可以看出,欧洲法典4,附件B.3.1中给出的减少调查的规则导致了不保守的结果,应予以修改。为了纠正这种情况,提出了一项修正案。

著录项

  • 来源
  • 会议地点 North Queensland(AU)
  • 作者单位

    Heavy Engineering Research Association, P.O. Box 76-134, Manukau, Auckland 2241, New Zealand;

    Civil and Natural Resources Engineering, Univ. of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand;

    Structural Systems, Heavy Engineering Research Association, P.O. Box 76-134, Manukau, Auckland 2241, New Zealand;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号