首页> 外文会议>Copper and Nickel / Extractive Metallurgy; Light Metals / Extractive Metallurgy >Current Density Distribution in a Cu Refining Electrolysis due to Geometrical Conditions
【24h】

Current Density Distribution in a Cu Refining Electrolysis due to Geometrical Conditions

机译:几何条件导致的铜精炼电解中的电流密度分布

获取原文
获取原文并翻译 | 示例

摘要

In the past a lot of investigations were done to increase the current density in copper electrolysis. At present the highest used average current density is in the range of 330 - 350 A/m~2. But current density figures of single cathodes in one cell are from lower than 200 A/m~2 to more than 600 A/m~2. The reasons for that are irregular geometrical conditions of the electrodes and bad electrical connections. Cathodic copper deposits were measured in dependence of the distances between the electrodes. The standard experiment was done with parallel distance between anode and cathode. For further experiments the cathodes were canted, bent and different distances were chosen. Afterwards the current density distribution on the cathodes was calculated.
机译:过去,进行了许多研究来增加铜电解中的电流密度。目前,使用的最高平均电流密度在330-350 A / m〜2的范围内。但是一个电池中单个阴极的电流密度值从低于200 A / m〜2到高于600 A / m〜2。其原因是电极的几何形状不规则和电连接不良。根据电极之间的距离测量阴极铜沉积物。在阳极和阴极之间平行距离的情况下进行标准实验。为了进行进一步的实验,将阴极倾斜,弯曲并选择不同的距离。之后,计算阴极上的电流密度分布。