【24h】

Optimisation of a full-scale activated sludge aeration process

机译:大规模活性污泥曝气工艺的优化

获取原文
获取原文并翻译 | 示例

摘要

A optimisation procedure for determining the better set point values (SP) of a multipoint on/off aeration controller has been developed and tested in the biological reactor (oxidation ditch) of a full-scale wastewater treatment facility. This procedure performs a study of the system with a simulation software and obtains the set of SP values using the Rosenbrock mathematical algorithm. The performance of the regulator with the optimised set of SP was compared with that obtained with a set of arbitrary values. A more stable system by about 30% (decrease of the start and stop operations, assuring thus, a longer life of the compressors) and energy savings about 17% are observed.
机译:已经开发了用于确定多点通/断曝气控制器的更好设定点值(SP)的优化程序,并在大型废水处理设施的生物反应器(氧化沟)中进行了测试。此过程使用仿真软件对系统进行了研究,并使用Rosenbrock数学算法获得了SP值集。将具有优化SP组的调节器的性能与通过一组任意值获得的性能进行比较。观察到系统更稳定约30%(减少了启动和停止操作,从而确保了更长的压缩机寿命),并且节省了约17%的能源。