Abstract: Two electric field profile analysis methods have been considered for evaluating the internal field distribution in cadmium telluride nuclear radiation detectors. A theoretical model is given, followed by two experimental measurements, using the induced radiation current pulse profile and the optical rotation by the Pockels effect of polarized IR light. Finally, theoretical and experimental results are discussed. !9
机译:摘要:已经考虑了两种电场轮廓分析方法来评估碲化镉核辐射探测器的内部场分布。给出了理论模型,随后进行了两次实验测量,使用了感应辐射电流脉冲轮廓和偏振红外光的普克尔斯效应引起的旋光。最后,讨论了理论和实验结果。 !9