首页> 外文会议>Healthy water environmental of buildings >The Experiment on Earthquake-proof Performance of Stainless Steel Piping with Pipe Fitting of the Mechanical Type for Water Supply Part 3 Relative-story Displacement Oscillation Experiments with Various Piping Diameters and Supports
【24h】

The Experiment on Earthquake-proof Performance of Stainless Steel Piping with Pipe Fitting of the Mechanical Type for Water Supply Part 3 Relative-story Displacement Oscillation Experiments with Various Piping Diameters and Supports

机译:机械式给水用管件的不锈钢管道的抗震性能试验第3部分各种管道直径和支座的相对位移振动试验

获取原文
获取原文并翻译 | 示例

摘要

This report shows the results of a relative-story displacement oscillation test conducted on vertical piping using thin-walled stainless steel pipes.The main purpose of this experiment is to investigate the influence of relative-story displacement oscillation on the vertical pipes with various diameters and supporting methods.In the previous research, the relative-story displacement oscillation test conducted on a vertical piping using thin-walled stainless steel pipes was reported, whereas no report on the piping that have various diameters and supporting methods.The shaking table test was conducted for pipes combined 14 kinds of vertical pipings and 2 kinds of piping support methods.In the case of simply supported, displacement of a small-sized piping with branch increased.The displacement of the vertical pipe without fitting is almost the same as the piping without branch piping.In addition, displacements of the fitting of the pipe was amplified, and large response displacement of the branch pipe connecting to the vertical pipe also occurred.It is apt to occure vibration when a small-sized piping is simply supported, which is close to actual constructional supporting.For this case, it needs consideration taking such measure as narraw supporting distance.In actual buildings, a vertical pipes without branch are used in many cases, where the simply support is commonly used.In addition, because response displacement of the branch pipe also occurs, it is nesesarry to choose the fitting that withstand the large repeated displacement between the vertical pipe and the branch.
机译:本报告显示了使用薄壁不锈钢管在垂直管道上进行的相对层位移振动测试的结果。本实验的主要目的是研究相对层位移振动对不同直径和直径的垂直管的影响。在以前的研究中,曾报道过使用薄壁不锈钢管在垂直管道上进行的相对层位移振动试验,而没有报道具有不同直径和支承方法的管道的振动台试验。适用于组合14种垂直管道和2种管道支撑方法的管道,在简单支撑的情况下,带有分支的小型管道的排量增加了,没有安装的垂直管道的排量几乎与没有分支的管道的排量相同另外,扩大了管件的位移,并且t的响应位移大分支管与垂直管的连接也发生了。当简单支撑小型管道时,容易发生振动,这接近实际的结构支撑。在这种情况下,需要考虑采取narraw支撑距离等措施。在实际建筑物中,通常使用无支管的垂直管,通常使用简单的支撑。此外,由于支管也发生响应位移,因此选择承受较大重复位移的配件非常麻烦。垂直管和分支。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号