In some applications, to increase the system power density and lower the system cost, the dc-link capacitance of PMSM drives needs to be reduced. However, such practice may cause considerable dc-link voltage fluctuation. In this study, a method is proposed to reduce the dc-link voltage fluctuation. By adjusting the sixth harmonic component of the inverter dc-link current, the proposed method can indirectly lower the dc-link capacitor current, thus reducing the dc-link voltage fluctuation. Compared with other voltage fluctuation reduction methods, the proposed method is independent of a controllable front-end rectifier, and it does not require any motor parameters. The simulation results show that the proposed method is feasible.
机译:在某些应用中,为了增加系统功率密度并降低系统成本,需要降低PMSM驱动器的直流链路电容。但是,这种做法可能会导致很大的直流母线电压波动。在这项研究中,提出了一种减小直流链路电压波动的方法。通过调节逆变器直流环节电流的六次谐波分量,该方法可以间接降低直流环节电容器的电流,从而减少直流环节的电压波动。与其他降低电压波动的方法相比,该方法独立于可控前端整流器,并且不需要任何电动机参数。仿真结果表明该方法是可行的。