首页> 外文会议>International Conference on Engineering MIS >Observer-based inter-turn short-circuit fault detection in closed-loop controlled induction machine
【24h】

Observer-based inter-turn short-circuit fault detection in closed-loop controlled induction machine

机译:闭环感应电机中基于观测器的匝间短路故障检测

获取原文

摘要

This paper deals with detecting of stator winding inter-turn short-circuits fault of induction machine operating under two control methods namely the backstepping control and the integral sliding mode control. The fault detection method is introduced, based on analysis of measured three-phase stator currents and estimated ones given by an unknown input observer. The difference between these behaviors, namely residuals, are used to detect the inter-turn short-circuits fault. Simulation results obtained from an induction machine with inter-turn short-circuits fault working under backstepping control and integral sliding mode control are presented.
机译:本文研究了感应电机定子绕组匝间短路故障的检测方法,即反步控制和整体滑模控制两种控制方法。介绍了一种故障检测方法,该方法基于对三相定子电流的测量分析和未知输入观测器给出的估计电流的分析。这些行为之间的差异(即残差)用于检测匝间短路故障。给出了在逆步控制和整体滑模控制下具有匝间短路故障的感应电机的仿真结果。