Reduction of convective heat losses in pulse tube refrigerators by additional DC flow

机译:通过额外的直流电减少脉冲管制冷机中的对流热损失

获取原文

摘要

The effectiveness of using an additional DC flow to improve cooling performance by reducing convective heat losses caused by gravity-driven secondary flow in inclined orifice pulse tube refrigerators was studied by visualization of flow and by measurement of gas temperatures at the cold and hot ends of the pulse tube. Results revealed that the gas temperature decreased at the cold end and increased at the hot end by decreasing the secondary flow to an optimal level in the core region. An additional DC flow thereby improved the cooling performance (temperature difference between hot and cold ends) by over 10%.
机译:通过可视化的流动以及在冷端和热端测量气体温度,研究了使用额外的直流电以减少倾斜孔脉冲管制冷机中重力驱动的二次流引起的对流热损失来改善冷却性能的有效性。脉冲管。结果表明,气体温度在冷端降低,而在热端升高,这是因为在芯区将二次流量降低到最佳水平。因此,额外的直流电将冷却性能(冷热端之间的温度差)提高了10%以上。