首页> 外文会议>International symposium on high voltage engineering >Second Round of Comparison Tests for High-Current Shunts in High-Power Laboratories in Asia and North America with an STL Reference Shunt
【24h】

Second Round of Comparison Tests for High-Current Shunts in High-Power Laboratories in Asia and North America with an STL Reference Shunt

机译:采用STL参考分流器的亚洲和北美大功率实验室中的大电流分流器的第二轮比较测试

获取原文

摘要

To establish traceability for high-current measurements, comparison tests of high-current shunts in high-power laboratories have been performed with short-circuit testing liaison (STL) reference shunts since 2005. The concept of the project involves providing only STL traceable shunts and leaving the remaining components needed to form a complete reference-measuring system to the laboratories themselves. Two STL reference shunts (hereinafter called reference shunts) were manufactured, one of which was used in Asia and the other in Europe and Africa. The reference shunts exhibit an rms value of 140 kA symmetrical current, and an asymmetrical peak current of 350 kA. The first round of the comparison tests finished in 2009, and the second round started in 2012. Before starting the second round of comparison tests, the two reference shunts were compared at the CRIEPI high-power testing laboratory in Japan in October 2011. The test results of the inter-comparison tests showed that the two reference shunts qualified as references. From 2012 to 2018, nineteen laboratories in Asia and North America attended comparison tests using the reference shunt for Asia and provided their test data for this paper. In this paper, we describe the comparison test results of shunts in high-power laboratories in Asia and North America in the second round. The test results showed that the shunts tested for the comparison tests performed well and most of the differences in the scale factor with the power frequency current between the reference shunt and those tested in participating laboratories were small.
机译:为了建立大电流测量的可追溯性,自2005年以来,已经通过短路测试联络(STL)参考分流器在大功率实验室中进行了大电流分流器的比较测试。该项目的概念仅涉及提供STL可追溯分流器和将形成完整参考测量系统所需的其余组件留给实验室本身。制造了两个STL参考分流器(以下称为参考分流器),其中一个在亚洲使用,另一个在欧洲和非洲使用。参考分流器的均方根值为140 kA对称电流,非对称峰值电流为350 kA。第一轮比较测试于2009年完成,第二轮于2012年开始。在开始第二轮比较测试之前,于2011年10月在日本的CRIEPI大功率测试实验室对两个参考分流器进行了比较。相互比较测试的结果表明,两个参考分流器有资格作为参考。从2012年到2018年,亚洲和北美的19个实验室使用针对亚洲的参考分流器进行了比较测试,并提供了本文的测试数据。在本文中,我们描述了第二轮亚洲和北美大功率实验室中分流器的比较测试结果。测试结果表明,为进行比较测试而测试的分流器性能良好,并且在参考分流器与参与实验室测试的分流器之间,比例因子与工频电流的大多数差异很小。

著录项

  • 来源
  • 会议地点 Budapest(HU)
  • 作者单位

    Central Research Institute of Electric Power Industry (CRIEPI) 2-6-1 Nagasaka Yokosuka-shi Kanagawa 240-0196 Japan;

    Korea Electrotechnology Research Institute (KERI) 12 Bulmosan-ro 10beon-gil Seongsan-gu Changwon-si Gyeongsangnam-do Korea;

    XI'AN High Voltage Apparatus Research Institute Co. Ltd (XIHARI) No. 18 North of No. 2 West Road Xi'an Shaanxi People's Republic of China;

    Central Power Research Institute (CPRI) STDS Govindpura Bhopal 462023 India;

    Eaton's Thomas A. Edison Technical Center Power Test Laboratories 11131 Adams Road Franksville WI 53126 USA;

  • 会议组织
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

    High-current; Measurement; Shunt;