An investigation was conducted to examine the cause of severe screen tube damage in the recovery boiler at VCP Luis Antonio mill. The results suggest that the problem was likely caused by impact of large pieces of deposits falling from the furnace roof and from the leading edge of superheater platens in the upper furnace. The problem has been reduced significantly by periodically monitoring the amount of deposit buildup on the furnace roof using a special camera; by installing an additional sootblower to minimize the deposit accumulation; by increasing the pressure and blowing frequency of sootblowers to minimize deposit build up in the problem-prone areas and by induced thermal shedding to control deposit size.
机译:进行了调查,以检查VCP路易斯安东尼奥工厂回收锅炉中严重的筛管损坏的原因。结果表明,该问题很可能是由于大块沉积物从炉顶和上部炉子的过热压板的前缘落下而造成的。通过使用专用摄像机定期监视炉顶上的沉积物堆积量,可以大大减少该问题;通过安装额外的吹灰器以最大程度地减少沉积物的堆积;通过增加吹灰器的压力和吹气频率以最大程度地减少在问题多发地区堆积的沉积物,并通过诱导热脱落来控制沉积物的大小。