Experiments showed that sudden contact with flowing molten smelt can result in tube temperature excursions of considerable magnitude. A frozen smelt layer on the tube surface reduces the magnitude of excursions and the water-side cooling environment plays a crucial role. A special probe was constructed that was capable of measuring both the heat flux and water-side heat transfer coefficient when the water-cooled probe was inserted into a molten smelt stream. All of the heat transfer coefficients, calculated from the temperature data, were in the transition boiling region. These results may have application to tube temperature excursions at primary air ports, which have been associated with tube cracking problems.
机译:实验表明,突然接触流动的熔体会导致相当大的管温偏移。管表面的冻结熔体层减少了偏移的幅度,水侧冷却环境起着至关重要的作用。构造了一个特殊的探头,当将水冷探头插入熔融熔炼流中时,它既可以测量热通量,又可以测量水侧的传热系数。根据温度数据计算出的所有传热系数都在过渡沸腾区域内。这些结果可能适用于一次风口处的管温偏移,这与管破裂问题有关。