首页> 外文会议>International Conference on Built Environment and Public Health(BEPH2004); 20041206-08; Shantou(CN) >Study on the factors Affect Variation of Indoor Air Formaldehyde Concentration
【24h】

Study on the factors Affect Variation of Indoor Air Formaldehyde Concentration

机译:影响室内空气甲醛浓度变化的因素研究

获取原文
获取原文并翻译 | 示例

摘要

The residents lived in the cold areas such as Harbin generally experience a residence time of approximately 6 months in chilly winter without frequent natural ventilation. To find out the influence of a short period of ventilation on the indoor formaldehyde concentration inside a new building, an investigation was conducted for the instance of twice ventilation in a day through window opening. The results showed that the indoor formaldehyde concentration increased with time after closing the window and followed an exponential function of C=C_0exp(-bt+(a+C_w)[1-exp(-bt] with correlation coefficient (R~2) of 0.945~0.999, based on the calculations for 14 groups of measurement data. The developed equation can be used to estimate the emission rate of indoor formaldehyde sources and the air exchange rate of the test room simultaneously.
机译:居住在哈尔滨等寒冷地区的居民通常在寒冷的冬天约需6个月的居住时间,而没有频繁的自然通风。为了找出短时间通风对新建筑物内室内甲醛浓度的影响,我们进行了一项调查,调查一天开窗两次通风的情况。结果表明,关闭窗户后,室内甲醛浓度随时间增加,并遵循C = C_0exp(-bt +(a + C_w)[1-exp(-bt])的指数函数,相关系数(R〜2)为0.945。 〜0.999,基于对14组测量数据的计算,所开发的方程可用于同时估算室内甲醛源的排放率和测试室的空气交换率。