A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC) was studied. The results show that: In summer automatic speed mode consumes the least refrigerating energy in different running modes, compared with low speed and high speed modes, it can conserve energy for 27.3% and 15.8%, respectively. In the same running mode, setting outer curtain can conserve energy for 40.9% and 20.4% compared with no curtain and inner curtain states, respectively. In winter high speed mode is the most efficient for saving energy which can decrease 40.3% and 30.9% compared with low speed and automatic speed modes. In the same running mode, setting inner curtain state makes the least heating energy consumption in cloudy day, about 10.8% and 2.7% less than no curtain and outer curtain states. However, it is not obvious when the day is fine. The heating energy consumption decreases as room temperature set point falls, compared with the energy consumption at 20.5℃ and 19.5℃, it is decreases for 34.1% andl7.0 % at 18.5℃, respectively. All the results will be the reference of environment design and control for air conditioning room.
机译:冬夏两季在长沙市某办公楼进行了实地调查,研究了不同运行方式,幕布样式和室温设定点对室内空调能耗的影响。结果表明:在夏季,自动模式在不同的运行模式下消耗的制冷量最少,与低速和高速模式相比,分别可节能27.3%和15.8%。在相同的运行模式下,相比于无帘和内帘状态,设置外帘可以分别节能40.9%和20.4%。在冬季,高速模式是最有效的节能方式,与低速和自动速度模式相比,可以降低40.3%和30.9%。在相同的运行模式下,设置内幕状态可使阴天的热能消耗最少,分别比无幕和外幕状态低约10.8%和2.7%。但是,天气晴朗的时候并不明显。随着室温设定点的降低,供暖能耗降低,与20.5℃和19.5℃的能耗相比,在18.5℃分别降低34.1%和17.0%。所有结果将为空调机房的环境设计与控制提供参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号