首页> 外文会议>International Conference on Enhanced Building Operations; 20061106-08; Shenzhen(CN) >Use of Plant Room Logbook Data to Establish Performance of a Cooling Production System
【24h】

Use of Plant Room Logbook Data to Establish Performance of a Cooling Production System

机译:使用机房日志数据建立制冷生产系统的性能

获取原文
获取原文并翻译 | 示例

摘要

In medium and large size air-conditioning (A/C) systems maintaining a logbook that has hourly data on operation of chillers and pumps is mandatory. The paper presents a methodology for establishing performance of a chilled water A/C system and applies the same for an office building in Kuwait. Data collected between March and October 2004 were analyzed. Inadequate control of supply water temperature and low chiller loading were identified as the key parameters leading to inefficiency of cooling production. This simple and low cost approach can be extremely valuable for medium size plants in capacity range of 100-250 RT, which are often without any other mechanism for performance data gathering such as plant room manager or building automation system.
机译:在中型和大型空调(A / C)系统中,必须维护日志,该日志具有每小时的冷却器和泵操作数据。本文介绍了一种建立冷水空调系统性能的方法,并将其应用于科威特的一栋办公楼。分析了2004年3月至2004年10月之间收集的数据。供水温度控制不当和冷水机组负荷低被认为是导致制冷生产效率低下的关键参数。对于容量范围为100-250 RT的中型工厂,这种简单且低成本的方法可能非常有价值,而这些工厂通常没有任何其他用于收集性能数据的机制,例如工厂机房经理或楼宇自动化系统。