A group of laboratory tests were conducted at Memorial University of Newfoundland with cylindrical ice specimens. The specimens were made with both laboratory ice and iceberg ice. In each test, the cylindrical specimen was triaxially confined at different pressure levels and an external constant deviatoric stress was exerted in the longitudinal direction. During the tests, some specimens showed a band of strain location in some cases leading to shear fracture. All those specimen showing strain localization or shear fracture made of laboratory ice were confined at relative low pressure levels (≤ 10 MPa) or high pressure levels (≥ 50 MPa). There was no strain localization or shear fracture observed at medium confinement levels. Strain localization or shear fracture observed in specimens made of iceberg ice was less pressure-dependent but initial flaws were observed in each specimen before the tests. Analysis shows that nonhomogeneity in the specimen is the likely cause of the localization. This has been confirmed by finite element simulations.
机译:在纽芬兰纪念大学用圆柱冰标本进行了一组实验室测试。用实验室冰和冰山冰制作样品。在每个测试中,将圆柱形试样三轴地限制在不同的压力水平下,并在纵向施加外部恒定的偏应力。在测试过程中,一些标本显示出一定的应变位置带,在某些情况下会导致剪切断裂。所有显示由实验室冰制成的应变局部化或剪切断裂的试样均被限制在相对低压水平(≤10 MPa)或高压水平(≥50 MPa)下。在中等限制水平没有观察到应变局部化或剪切断裂。在冰山冰制的标本中观察到的应变局部化或剪切断裂对压力的依赖性较小,但在测试前在每个标本中均观察到了初始缺陷。分析表明,样品中的不均匀性可能是定位的原因。这已经通过有限元模拟得到了证实。