The Finnish utility TVO has developed a simulation model that allows realistic estimation both of the frequency and of the duration distribution of the Loss Of Offsite Power (LOOP) on a Nuclear Power Plant (NPP). The model is based on the failure rates and recovery time distributions for failures of the components between the station service bus bars of the unit and the external grid. Communication between the control room personnel and the personnel of the grid company, as well as the tasks performed by personnel of the grid company have been modelled. The model has been used in the detailed design of the modifications of the connections from the NPP to the external grid, but also in configuration control of the 400 kV and 110 kV substations close to the NPP. The results have also been used in training all parties participating the maintenance of the grid and recovery of the connections.
机译:芬兰公用事业TVO已经开发了一种仿真模型,可以对核电站(NPP)上的异地电力损耗(LOOP)的频率和持续时间分布进行现实的估算。该模型基于故障率和单元的站服务母线与外部电网之间组件故障的恢复时间分布。控制室人员与电网公司人员之间的通信,以及电网公司人员执行的任务均已建模。该模型已用于从NPP到外部电网的连接的修改的详细设计中,而且还用于靠近NPP的400 kV和110 kV变电站的配置控制中。该结果还用于培训所有参与维护电网和恢复连接的各方。