首页> 外文会议>International Structural Engineering and Construction Conference(ISEC-03); 20050920-23; Shunan(JP) >Initial drying period of an in situ cast massive concrete ground slab and the fulfillment of the covering criteria
【24h】

Initial drying period of an in situ cast massive concrete ground slab and the fulfillment of the covering criteria

机译:现浇大块混凝土地面的初始干燥期及覆盖标准的满足

获取原文
获取原文并翻译 | 示例

摘要

The objective of this research was to examine the thermal and moisture behaviour of an in situ cast concrete slab with embedded floor heating elements during the initial drying period of the structure. Another objective was to examine the effect of floor heating on the fulfilment of the common covering criteria. Rapid changes in heating power, i.e. temperature changes of embedded heating elements have a major influence on the moisture humidity levels of the surrounding concrete. When determining the relative humidity of a massive concrete slab for the floor covering criteria, the measurement should always be performed in operational temperatures and at the section between the elements outside the range of the drier zone surrounding the heated conduit. The equivalent measuring depth should be in both cases 0.4 X total height of the concrete slab.
机译:这项研究的目的是在结构的初始干燥期间检查具有嵌入式地板加热元件的现浇混凝土板的热和湿气行为。另一个目标是研究地板采暖对共同覆盖标准的实现的影响。加热功率的快速变化,即嵌入式加热元件的温度变化,对周围混凝土的湿气湿度水平有重大影响。在确定用于地板覆盖标准的块状混凝土板的相对湿度时,应始终在工作温度下以及在围绕加热管道的干燥区范围之外的元件之间的区域中进行测量。两种情况下的等效测量深度均应为混凝土板总高度的0.4X。