We compared three conspicuity tests applied to four full field digital mammography (FFDM) systems. The tests included: 1) the calculation of noise equivalent quanta (NEQ); 2) contrast-detail analysis with the CDMAM 3.4 phantom and 3) evaluation of the detectability of (simulated) microcal-cifications with specific well-known dimensions in mastectomy images. For each contrast-resolution test method, the exposure, processing and viewing conditions were identical. As a result, the only variable for a given test was the physical performance of the detector. The three test methods each rank the detectors in the same order. The flat-panel detector ranked the best overall, the dual-sided read-out storage phosphor detector ranked second and the single-sided-read-out storage phosphor detectors with 50 μm and 100 μm pixel sizes ranked similarly and were inferior to the other 2 detectors.
机译:我们比较了应用于四个全场数字乳房X线摄影(FFDM)系统的三个显着性测试。测试包括:1)噪声等效量(NEQ)的计算; 2)使用CDMAM 3.4体模进行对比细节分析,以及3)评估乳房切除术图像中具有特定的已知尺寸的(模拟)微缩显微镜的可检测性。对于每种对比度分辨率测试方法,曝光,处理和观察条件都相同。结果,给定测试的唯一变量是检测器的物理性能。三种测试方法均以相同的顺序对检测器进行排序。平板探测器总体上排名最佳,双面读出式存储磷光体排名第二,像素尺寸为50μm和100μm的单面读出式存储磷光体排名相近,次于其他2个探测器。