首页> 外文会议>Medical Measurements and Applications, 2009. MeMeA 2009 >Characterisation of a coding/reconstruction algorithm on MRI simulated noisy data
【24h】

Characterisation of a coding/reconstruction algorithm on MRI simulated noisy data

机译:MRI模拟噪声数据上编码/重构算法的表征

获取原文

摘要

In Magnetic Resonance Imaging (MRI), the presence of static magnetic field in-homogeneities introduces distortions and artifacts in the images. A coding/reconstruction algorithm for MRI, based on the assignment of different time varying frequencies (accelerations) to different spatial positions, has been tested on simulated noisy data. Results, demonstrating the method is not conditioned neither by the presence of static magnetic field in-homogeneity nor by the presence of noise, are reported. In particular, the results demonstrated that noise was not incremented and the signal was unaffected by blurring or distortions.
机译:在磁共振成像(MRI)中,静态磁场的不均匀性会在图像中引入失真和伪影。已经在模拟噪声数据上测试了基于对不同空间位置分配不同时变频率(加速度)的MRI编码/重建算法。结果表明,该方法既不受静磁场的不均匀性的影响,也不受噪声的影响。尤其是,结果表明噪声不会增加,并且信号不会受到模糊或失真的影响。