首页> 外文会议>Electrical Insulation Conference >Insulation system for internal connectors in gas cooled turbine generators
【24h】

Insulation system for internal connectors in gas cooled turbine generators

机译:气冷涡轮发电机内部连接器的绝缘系统

获取原文

摘要

From this series of test bars. the following conclusions regarding phase lead insulation have been drawn: 1. A silicone rubber insulation system comprised of the molded tape and paste combination exhibits good insulation properties even when subjected to as much as twice normal operating temperatures. 2. A silicone rubber insulation system comprised of self fusing tape deteriorates under heat and bulges when continued by protective glass tape. 3. Asphalt mica tape used as connection insulation indicates internal heating as demonstrated by dielectric tests. 4. Epoxy mica tape, although losing some of its binder when overheated, remains relatively unchanged under heat and dielectric tests. When used for field repairs of connection insulation, it can be left to cure under normal machine operating temperatures.
机译:来自这一系列的测试条。得出以下有关相线绝缘的结论:1.即使模制的胶带和糊剂组合构成的硅橡胶绝缘系统,即使经受两倍于正常工作温度的温度,仍具有良好的绝缘性能。 2.由自熔胶带组成的硅橡胶绝缘系统在加热时会变质,在继续使用保护性玻璃胶带时会凸出。 3.介电测试表明,用作连接绝缘体的云母带表示内部发热。 4.环氧云母带,尽管在过热时会失去一些粘合剂,但在热和介电测试下仍保持相对不变。当用于连接绝缘的现场维修时,可以在正常的机器工作温度下固化。