Analyses have been completed to evaluate differentoperating strategies for the Hijiori Long TermCirculation Test (LTCT). To ensure that theGeocrack2D model used to represent the LTCT wasvalid, 1991-1996 testing at Hijiori was firstsimulated. After reasonable matches were obtainedwith the existing data, the model was used to predictbehavior during the two year long LTCT. Five caseswere analyzed: (1) a nominal case with injectionflow of 16 kg/s, (2) a case with half the nominal flow,(3) a case with double the nominal flow, (4) a casewhere HDR-2a was blocked at the lower fracture(selected to block the observed cold flow at the lowerfracture in HDR-2a), and (5) a case with enhancedconnectivity between the lower and upper fracture.In all cases, injection was in HDR-1, with productionfrom HDR-2a and HDR-3.For the nominal case, the HDR-2a mixed productiontemperature is predicted to reduce from 240 C to 180C while the HDR-3 temperature remainsapproximately constant at 240 C. The highestproduction temperatures occur for Case 4, when thelower fracture is blocked in HDR-2a, with the finalproduction temperature after two years being 214 C.
机译:分析已经完成以评估不同 Hijiori长期的经营策略 循环测试(LTCT)。为了确保 用于表示LTCT的Geocrack2D模型是 有效,1991-1996年在Hijiori进行的测试是第一次 模拟。在获得合理的匹配之后 根据现有数据,该模型用于预测 在为期两年的LTCT中的行为。五例 分析:(1)注射名义病例 流量为16 kg / s,(2)是标称流量的一半的情况, (3)公称流量两倍的情况,(4)一种情况 HDR-2a在下骨折处受阻 (选择此选项可阻止在下方观察到的冷流 HDR-2a骨折),以及(5) 上下骨折之间的连通性。 在所有情况下,注射都是在HDR-1中进行的, 来自HDR-2a和HDR-3。 对于名义情况,HDR-2a混合生产 预计温度将从240摄氏度降低至180摄氏度 ,而HDR-3温度保持不变 大约在240°C恒定。最高 情况4会产生生产温度 下骨折在HDR-2a中受阻,最终 两年后的生产温度为214C。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号