首页> 外文会议>Conference on physiology and function from multidimensional images >Improved bolus localization for videodensitometry
【24h】

Improved bolus localization for videodensitometry

机译:改进了视频囊炎的推注定位

获取原文

摘要

Videodensitometric measurement of blood flow requires injection of spatially varying contrast density with minimal perturbation of the flow. Constant injection does not yield sufficient spatial gradients for flow measurement during peak flow and diastole, whereas pulsed injection superposes a time- varying perturbation on the measured flow. In order to avoid these drawbacks, we propose to pre-load the catheter injection tubing with spatially varying contrast density. This allows us to generate spatially localized contrast profiles in phantoms and to inject temporally varying contrast profiles in vivo without pulsatile injection. In phantom experiments we obtain better spatial localization of bolus using pre-loading than by pulsed injection of pure contrast material. Preliminary results indicate improvement in accuracy of blood flow measurements using pre-loaded bolus.
机译:血流的视频囊计量测量需要在流动的最小扰动中注射空间不同的对比度密度。恒定注射不会产生足够的空间梯度,以便在峰流动和舒张期间流动测量,而脉冲注射率在测量的流动上逐渐变化。为了避免这些缺点,我们建议预先装载导管注入管,具有空间不同的对比度密度。这允许我们在幽灵中产生空间局部局限性的对比度曲线,并在没有脉动注射的情况下在体内注入时间上变化的对比度。在Phantom实验中,我们使用预装载比通过脉冲喷射的纯对比材料获得更好的推注的空间定位。初步结果表明使用预先装载的推注的血流测量精度的提高。