A systematic investigation has been carried out on the tilt and azimuth angle dependencies of output characteristics of photovoltaic modules. The measurements have been made on some combinations of two prototype modules of poly-Si solar cells, installed at different tilt angles and azimuth angle. Output parameters were measured in the form of I-V characteristics.The analysis of the results shows that (i) provided output voltage is appropriate to the system operation, no serious problems are likely to arise out of the parallel connection of two modules at different tilt and/or azimuth angles, if protected by blocking diodes (ii) in the case of series connection equipped with by-pass diodes, however, the max-power voltage (Vmp) becomes instable if the azimuth angle is 15 degrees or more different from each other. That is because the Vmp drops down to the Vmp level of the higher output-current module.
机译:已经对光伏模块的输出特性的倾斜和方位角依赖性进行了系统的研究。已经对以不同倾斜角和方位角安装的多晶硅太阳能电池的两个原型模块的某些组合进行了测量。输出参数以I-V特性的形式进行测量。 结果分析表明(i)如果输出电压适合系统操作,则在两个模块以倾斜和/或方位角不同的情况下并联连接时,如果受阻二极管的保护,则不会出现严重的问题( ii)在串联连接有旁路二极管的情况下,如果方位角彼此相差15度或更大,则最大功率电压(Vmp)变得不稳定。这是因为Vmp下降到较高输出电流模块的Vmp电平。