The Seismic Proving Test on Reactor Shutdown Cooling Systems was conducted to confirm the integrity of system functions required during earthquakes. The tests were completed in February 1994 using the shaking table at Tadotsu Engineering Laboratory of NUPEC. As the results of the tests, it was found that pressure pulsation resulting from pressure response wave in piping systems was caused by excitation. However, there were no problems with maintaining system functions up to 1.5 times of the S_2 input wave, which was generated to envelope the response spectrum of each floor on which was generated to envelope the response spectrum of each floor on which the system facilities and components are installed.
机译:进行了反应堆关闭冷却系统的抗震验证测试,以确认地震期间所需系统功能的完整性。测试在1994年2月使用NUPEC的Tadotsu工程实验室的振动台完成。作为测试结果,发现由管道系统中的压力响应波引起的压力脉动是由激励引起的。但是,将系统功能维持到S_2输入波的1.5倍是没有问题的,它的产生是为了覆盖每个楼层的响应频谱,而在该楼层上生成的信号是为了覆盖系统设施和组件所在的每个楼层的响应频谱已安装。