首页> 外文会议>International heat transfer conference;IHTC1998 >Error analysis of heat flux measurement on membrane waterwalls
【24h】

Error analysis of heat flux measurement on membrane waterwalls

机译:膜式水冷壁热通量测量的误差分析

获取原文

摘要

A new approach has been presented by the authors to solve a category of inverse conduction problems in linear systems with concern in its application in steady heat flux measurement. A particular example is to determine local heat fluxes on membrane walls in experimental and in-situ studies of heat transfer in circulating fluidized bed (CFB) and traditional boiler furnaces. The basic idea is to measure temperatures at certain locations in the membrane wall itself and then to derive the heat flux on the surface. In this paper, the error transmission in this method is further studied by means of theoretical analysis and computer simulations. Influence of the error in the heat transfer coefficient inside the tubes on the heat flux measurement is investigated. The influences of other facotrs on the error transmission are also discussed such as locations where the temperature sensors are installed.
机译:作者提出了一种新方法来解决线性系统中的一类逆传导问题,并关注其在稳定热通量测量中的应用。一个特定的示例是在循环流化床(CFB)和传统锅炉炉中传热的实验和现场研究中确定膜壁上的局部热通量。基本思想是测量膜壁本身某些位置的温度,然后得出表面的热通量。在本文中,通过理论分析和计算机仿真进一步研究了该方法中的误差传递。研究了管内传热系数误差对热通量测量的影响。还讨论了其他因素对错误传输的影响,例如安装温度传感器的位置。