【24h】

ANALYSIS OF PERFORMANCE OF AIR SOURCE HEAT PUMP OPERATING IN WINTER

机译:冬季空气源热泵运行性能分析

获取原文

摘要

Air source heat pump (ASHP) with no cooling water system is more convenient than water-cooled chiller in installation, operation and maintenance, etc. It can serve for building both in summer and in winter without other heat source equipment such as boiler. China has a large territory. She crosses four climate zones. Four seasons can be distinguished easily around the middle and lower reaches of Yangtze River, where it's cold in winter and hot in summer. But in whiter, there is no extremely cold day. In this district, it needs cooling in summer and heating in winter. There are many factors in the choice of air-conditioning's cold and heat source. ASHP has become one of the most popular products for its merits. In the paper, the site tests have processed with air-source heat pump operation in some public buildings. And their energy performance has been analyzed. From the point of energy efficiency view, the prospect for the air-source heat pump's wide application is not so excited.
机译:不带冷却水系统的空气源热泵(ASHP)在安装,操作和维护等方面比水冷式制冷机更方便。它可以在夏季和冬季用于建筑物,而无需使用其他热源设备(例如锅炉)。中国地域辽阔。她跨越四个气候区。长江中下游地区很容易区分四个季节,冬季寒冷,夏季炎热。但更白的是,没有特别寒冷的一天。在这个地区,夏季需要制冷,而冬季则需要供暖。选择空调冷热源的因素很多。凭借其优点,ASHP已成为最受欢迎的产品之一。在本文中,在一些公共建筑中使用空气源热泵运行进行了现场测试。并对其能量性能进行了分析。从能源效率的角度来看,空气源热泵的广泛应用前景并不乐观。