Experimental Research on Fire Damage of Tunnel Lining Concrete Test Blocks

机译:隧道衬砌混凝土试块火灾破坏的试验研究

获取原文

摘要

In tunnel fire, lining concrete can be damaged to different degrees according to the water content of concrete and the temperatures it is subjected to. Three groups of C25 concrete standard test blocks with different water content were heated for 5 hours at different constant temperature respectively and put aside after being cooled. Then compressive tests and splitting tensile tests were carried out to investigate the influence of water content and temperature on the residual strength of the concrete test blocks. The results show that, Water content is the main factor causing bursting of concretes at high temperature. When temperature is below 200°C, higher water content is prevail to enhancing the residual compressive strength of concrete. After high temperature, the splitting tensile residual strength of concrete loses much quicker than the compressive residual strength, and that higher water content would aggravate the reduction of its tensile performance.
机译:在隧道火灾中,衬砌混凝土会根据混凝土的含水量和所承受的温度而受到不同程度的破坏。将三组不同含水量的C25混凝土标准试块分别在不同的恒温下加热5小时,冷却后置于一旁。然后进行压缩试验和劈裂拉伸试验,以研究含水量和温度对混凝土试块残余强度的影响。结果表明,含水量是引起高温下混凝土爆裂的主要因素。当温度低于200°C时,较高的水含量占主导地位,以提高混凝土的残余抗压强度。高温后,混凝土的劈裂抗拉残余强度比抗压残余强度损失快得多,而且较高的水含量会加剧其抗拉性能的降低。