Regenerative peripheral nerve interfaces (RPNIs) transfer motor and sensory signals between amputee and prosthesis. Von Frey (VF) monofilaments are used clinically to evaluate sensory feedback but have not been validated at locations used in our rodent studies. Our purposes were to determine VF sensory test reliability at the ankle and thigh, and to evaluate sensory function of Mixed Nerve (MN) and Sensory Nerve (SN) RPNIs. For reliability testing, VF monofilaments were applied to Normal rats at the ankle and thigh in an up-down pattern. Paw Withdraw Thresholds were determined by alternately exceeding and reducing filament pressure. VF tests were then administered to experimental MN-RPNIs or SN-RPNIs. Reliability results at the ankle showed sensation did not vary over six weeks. At the thigh, reliability was similar during week 0 and 1, but with further testing sensation increased. Comparison between location found at weeks 0 and 1, the ankle was significantly more sensitive than the thigh (p<0.05). VF administration to experimental animals revealed that the MN-PRNI group was significantly less sensitive than both the SN-RPNI and Normal groups (p<0.05); while the SN-RPNI and Normal groups did not differ. VF monofilament testing was reliable and successful at distinguishing between sensations of normal skin with dense sensory endings (ankle) and disperse sensory endings (thigh). VF testing successfully discriminated between mixed and sensory nerve RPNI groups.
机译:再生性周围神经接口(RPNI)在截肢者和假体之间传递运动和感觉信号。冯·弗雷(VF)单丝在临床上用于评估感觉反馈,但尚未在我们的啮齿动物研究中使用的位置得到验证。我们的目的是确定足踝和大腿的VF感觉测试可靠性,并评估混合神经(MN)和感觉神经(SN)RPNI的感觉功能。为了进行可靠性测试,将VF单丝以上下模式应用到正常大鼠的脚踝和大腿上。通过交替超过和降低细丝压力来确定爪子抽出阈值。然后将VF测试应用于实验性MN-RPNI或SN-RPNI。脚踝的可靠性结果表明,感觉在六周内没有变化。在大腿上,第0周和第1周的可靠性相似,但随着进一步的测试感觉增加。在第0周和第1周发现位置之间的比较,脚踝比大腿明显敏感(p <0.05)。对实验动物进行VF给药后发现,MN-PRNI组的敏感性明显低于SN-RPNI组和正常组(p <0.05)。而SN-RPNI和普通组没有差异。 VF单丝测试在区分具有密集的感觉末梢(脚踝)和分散的感觉末梢(大腿)的正常皮肤的感觉方面是可靠且成功的。 VF测试成功地区分了混合神经和感觉神经RPNI组。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号