首页> 外文会议>European Photovoltaic Solar Energy Conference and Exhibition >Partial Discharge Tests on Complete PV Modules in Comparison to the Standardised Test of Back Sheet Samples
【24h】

Partial Discharge Tests on Complete PV Modules in Comparison to the Standardised Test of Back Sheet Samples

机译:完整光伏组件的局部放电测试与背板样品的标准化测试相比

获取原文

摘要

To ensure the long-term insulation of back sheets of photovoltaic modules under electrical stress partial discharge (PD) tests are performed. The relevantstandard specifications IEC 60270 and IEC 61730 define the current state of the test performed on single samples of the back sheet inserted in a specialelectrode configuration. Up to now it is not well-understood, whether the results can be transferred to the final product of a PV module in all cases. Therefore thegoal of this investigation is the development of a test method to perform PD measurements on a factory built PV module. To investigate the complete PV moduleat once a counter electrode consisting of salt water is used, which is able to adapt perfectly to the unevenness of the back side of the module.
机译:为了确保在电应力下进行光伏模块背板的长期绝缘,需要进行局部放电(PD)测试。相关的 标准规范IEC 60270和IEC 61730定义了对插入特殊材料的背板的单个样本执行的测试的当前状态 电极配置。到目前为止,是否可以在所有情况下将结果转移到PV模块的最终产品尚不为人所知。因此 这项研究的目标是开发一种测试方法,以对工厂制造的PV模块进行PD测量。研究完整的光伏组件 立即使用由盐水组成的对电极,该电极能够完美地适应模块背面的不平整。