Ventilation and IAQ in Homes Receiving Energy Efficiency Retrofits

机译:进行节能改造的房屋中的通风和室内空气质量

获取原文

摘要

Residential energy efficiency programs in the United States have become increasingly aware of the need to consider the indoor air quality impacts of the energy-based measures that are implemented. This has resulted in a shift from referencing outdated ventilation standards to incorporating ASHRAE Standard 62.2. Because this shift has resulted in substantial concern from program implementers regarding the cost of increased ventilation requirements, research on any benefits of this change is warranted. This presentation provides preliminary data from such a study. This study, which is still underway, implements the older ventilation standard in half of the homes and the current standard in the other half. In all homes, building air leakage reductions are measured before and after retrofit, along with indoor concentrations of a number of common contaminants, including carbon monoxide, carbon dioxide, formaldehyde, total VOCs, radon, and humidity. Existing ventilation is characterized, and additional ventilation to meet the applicable ventilation standard is documented. In addition, health surveys are administered to the occupants before retrofit and a minimum of 6 months after retrofit. This presentation will discuss changes in contaminant concentrations from before to after retrofit, corrected for outdoor weather factors. These changes will be evaluated separately by which of the two ventilation standards was used. Additionally, the total ventilation rates for the two groups will be presented, and the contaminant concentrations will be analyzed based on total ventilation rate, including natural and mechanical sources. Results of the health surveys will not be presented because at this time the sample size of fully completed houses is too small to draw any preliminary conclusions. Because the study is still underway the data presented should not be considered as representing the final conclusions of the study.
机译:美国的住宅能效计划越来越意识到需要考虑已实施的基于能源的措施对室内空气质量的影响。这导致从参考过时的通风标准转变为纳入ASHRAE标准62.2。由于这种转变已引起计划实施者对增加通风需求的成本的重大关注,因此有必要对这种变化的任何好处进行研究。本演示文稿提供了此类研究的初步数据。这项仍在进行中的研究在一半房屋中采用了较旧的通风标准,在另一半房屋中采用了现行标准。在所有家庭中,建筑物的空气泄漏减少量都是在改造前后进行测量的,同时还测量了室内各种常见污染物的浓度,包括一氧化碳,二氧化碳,甲醛,总VOC,ra和湿度。对现有通风进行了表征,并记录了符合适用通风标准的其他通风。此外,在翻新前和翻新后至少6个月对居住者进行健康检查。本演讲将讨论改造前后污染物浓度的变化,并针对室外天气因素进行了校正。这些变化将通过使用两种通风标准中的哪一种进行单独评估。此外,还将介绍两组的总通风量,并根据总通风量(包括自然和机械源)分析污染物浓度。健康调查的结果将不会显示,因为此时完全建成的房屋的样本量太小,无法得出任何初步结论。由于研究仍在进行中,因此所提供的数据不应视为代表研究的最终结论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号