首页> 外文会议>International Conference on Systems and Informatics >Economic analysis of hot secondary-air heating desulfurized clean flue gas in 1000 MW unit
【24h】

Economic analysis of hot secondary-air heating desulfurized clean flue gas in 1000 MW unit

机译:1000 MW机组热二次风加热脱硫清洁烟气的经济分析。

获取原文

摘要

Based on technological principle and operation characteristics of wet flue gas desulfurization system in the thermal power plant, the causes and influencing factors of gypsum rain were analyzed from three aspects, including equipment structure, operation parameters and environmental factors. Furthermore, control measures corresponding to the design of wet flue gas desulfurization system and operation adjustment were proposed. Focusing on a certain 1000MW unit, a method applying hot secondary-air to heat desulfurized clean flue gas was put forward to improve flue gas temperature in absorber tower outlet. Meanwhile, according to the thermodynamic calculation in various operating conditions, economic effect on unit was summarized while adopting the above method to control gypsum rain.
机译:根据火电厂湿法烟气脱硫系统的技术原理和运行特点,从设备结构,运行参数和环境因素三个方面分析了石膏雨的成因及影响因素。提出了相应的湿法烟气脱硫系统设计及运行调整的控制措施。针对某某1000MW机组,提出了利用热二次空气加热脱硫的清洁烟气的方法,以提高吸收塔出口烟气的温度。同时,根据各种工况下的热力学计算结果,总结了采用上述方法控制石膏雨水对机组的经济效益。